Sign In | Join Free | My tjskl.org.cn |
|
The SVG (Static Var Generator) operates by connecting a voltage-source converter (VSC), composed of a self-commutated bridge circuit using IGBT devices, in parallel with the power grid through a transformer or reactor. By controlling the switching of the IGBT modules, the DC voltage is converted into an AC output with adjustable amplitude and phase.
For an ideal SVG with negligible active power loss, reactive power compensation is achieved solely by adjusting the output voltage amplitude:
When the output voltage is lower than the grid voltage, the SVG operates in an inductive mode, absorbing reactive power (acting like a reactor).
When the output voltage is higher than the grid voltage, it operates in a capacitive mode, supplying reactive power (acting like a capacitor).
SVG systems are categorized into:
Direct-connection type: typically used for 6kV, 10kV, and 35kV applications.
Step-down connection type: generally applied on a 10kV low-voltage side.
The choice of connection depends on the grid voltage level at the point of interconnection and the required compensation capacity.
The system uses a cascaded H-bridge topology, and the connection structure can be configured as either star (Y) or delta (Δ), depending on the application requirements.
1. Intelligent Human-Machine Interaction, Simplified Commissioning
FGSVG features an intelligent startup self-check function, significantly reducing commissioning complexity and shortening the deployment cycle. With intuitive operation and optimized user interface, it delivers a seamless user experience for operators and maintenance teams.
2. Advanced Recording and Diagnostic Functions
Equipped with real-time waveform recording and fault trace analysis, including a 16-channel oscilloscope function, FGI’s SVG enables precise monitoring and fast troubleshooting during operation.
3. Self-Adaptive Phase Sequence Recognition
No need to manually determine phase sequence — the system automatically identifies and adapts, further streamlining installation.
4. Multi-Level Networking, Seamless Capacity Expansion
FGSVG supports high-speed optical fiber communication (10M/10km), enabling ring-networked, master-slave parallel operation across multiple devices. This design supports easy reactive power capacity expansion, fully addressing users’ scalability concerns.
5. Intelligent Operating Mode Switching
The system automatically switches between normal and fault operating modes. Especially useful in critical applications such as railway substations where automatic adaptation is needed during bus tie switch operations.
6. Remote Monitoring via APP & Flexible Communication Interfaces
Monitor industrial equipment anytime, anywhere via mobile APP. FGI SVG offers rich communication interfaces including RS485, CAN, Ethernet, and GPRS. It is fully compatible with major industry protocols such as Modbus-RTU, Profibus, CDT91, and IEC104.
Utilizing instantaneous reactive power theory, the controller achieves a response time of ≤1ms and full power response within 5ms. This ensures fast and accurate compensation for demanding applications such as steelmaking, lifting, and impact loads. The system dynamically adjusts reactive power, maintains optimal power factor, and turns low power factor penalties into performance rewards.
Power Quality Enhancement and System Balance
The device suppresses negative sequence currents caused by load imbalances, ensuring balanced three-phase output. It mitigates harmonics up to the 13th order, protecting transformers, motors, capacitors, and communication systems from overheating, instability, or interference.
Flexible Operating Modes and Seamless Adaptation
Supports multiple modes: constant reactive power, power factor, voltage control, negative sequence compensation, and more. Real-time mode switching and user-defined curves meet various on-site requirements, while adaptive voltage regulation allows the device to handle fluctuations and flicker without manual intervention.
High Reliability and Safety-Oriented Design
Equipped with multi-level protection across components, systems, and the entire device, it rapidly responds to faults such as overload or overcurrent. Built-in early warning monitors key temperatures and triggers alarms to prevent issues like fan failures or filter blockages.
Real-Time Monitoring and Diagnostic Intelligence
Offers full waveform capture, harmonic analysis, and system data display. Black box recording stores 100ms of data before and after any fault event, allowing precise diagnosis and fast maintenance.
Easy Integration and Scalable Architecture
Modular design simplifies installation and maintenance. Rich communication interfaces (Ethernet, RS485, CAN, fiber optic) with MODBUS, ProfiBUS, and IEC61850 protocols support remote control and monitoring. Multiple units can operate in parallel with automatic switching in case of individual unit failure, enabling flexible system expansion.
Built to Withstand Harsh Environments
Available with IP44-rated enclosures for dust- and moisture-prone areas. Designed to comply with EMC standards, the system ensures stable operation in electrically noisy settings. Optional dual power supplies (AC/DC) enable seamless hot-swapping during outages.
Technical Specifications
Name | Specification |
Rated voltage | 33kV±10%~38.5kV±10% |
Assessment point voltage | 33kV±10%~38.5kV±10% |
Input voltage | 0.9~ 1.1pu; LVRT 0pu(150ms), 0.2pu(625ms) |
Frequency | 50/60Hz; Allow short-term fluctuations |
Output capacity | ±0.1Mvar~±200 Mvar |
Starting power | ±0.005Mvar |
Compensation current resolution | 0.5A |
Response time | <5ms |
Overload capacity | >120% 1min |
Power loss | <0.8% |
THDi | <3% |
Control power | 380VAC, 220VAC/220VDC |
Reactive power regulation mode | Capacitive and inductive automatic continuous smooth adjustment |
Communication interface | Ethernet, RS485, CAN, Optical fiber |
Communication protoco | Modbus_RTU, Profibus, CDT91, IEC61850- 103/104 |
Running mode | Constant device reactive power mode, constant assessment point reactive power mode, constant assessment point power factor mode, constant assessment point voltage mode and load compensation mode |
Parallel mode | Multi machine parallel networking operation, multi bus comprehensive compensation and multi group FC comprehensive compensation control |
Protection | Bus overvoltage, bus low voltage, SVG overcurrent, drive fault, module overvoltage, overcurrent, overtemperature and communication fault; Protection input interface, protection output interface, abnormal system power supply and other protection functions. |
Fault handling | Adopt redundant design to meet N-2 operation |
Cooling mode | Water cooling/Air cooling |
IP degree | IP30(indoor); IP44(outdoor) |
Storage temperature | -40℃~+70℃ |
Running temperature | -35℃~ +40℃ |
Humidity | <90% (25℃), no condensation |
Altitude | <=2000m (above 2000m customized) |
Earthquake intensity | Ⅷ degree |
Pollution level | Grade IV |
Indoor Cleanliness
Ensure the installation environment is clean and dry. Accumulated dust may affect system performance and cooling.
Pest Control
Implement anti-rodent measures to prevent small animals from entering the SVG cabinet and causing damage.
Temperature Management
Maintain an indoor ambient temperature below 38°C. When temperatures rise, use ventilation or air conditioning to cool the area.
Post-Startup Fastening Check
About one week after commissioning, shut down the device and disconnect the main power. Tighten all conductive connections, grounding screws, and bolts to ensure reliable contact.
Daily Inspection
Inspect SVG status daily. If unusual noises are heard, airflow is weak or absent, or abnormal smells (especially ozone) are detected:
Immediately shut down and disconnect power.
Check for obstructions in the air intake, clogged exhaust ducts, or fan failure.
Replace cooling fans or clean ducts as needed.
Contact the manufacturer if persistent abnormality occurs.
Schedule a shutdown at least once per year to inspect internal components:
Open one power unit and examine the capacitors.
Ensure film capacitors have a smooth, glossy black surface and intact seals.
Location: Zhengzhou City, Henan Province
Compensation Capacity: -2000kvar to +2000kvar
System Voltage: 6kV
Load Characteristics:
Compared to arc furnaces, ferroalloy (submerged arc) furnaces are more stable. However, the site encountered serious three-phase load imbalance and a low power factor.
Compensation Results:
Significant reduction in three-phase imbalance
Power factor improved to meet utility requirements
Stable operation of the furnace under optimized power conditions
Location: Yantai City, Shandong Province
Compensation Capacity: -10000kvar to +10000kvar
System Voltage: 35kV
Load Characteristics:
Due to the intermittent nature of wind resources, the system suffered from frequent voltage fluctuations, with instantaneous power factor dropping as low as 0.81.
Compensation Results:
System voltage stabilized within 35.5–35.7kV
Meets national standard GB/T 12325-2008 (Voltage Deviation Assessment)
Real-time power factor raised to 0.96
Complies with GB/T 14549-1993 (Harmonics in Public Power Grid)
Supports Low Voltage Ride-Through (LVRT) requirements
Location: Xuzhou City, Jiangsu Province
Compensation Capacity: -4000kvar to +4000kvar
System Voltage: 6kV
Load Characteristics:
The load exhibits a wide frequency spectrum with serious harmonic current distortion, especially at the 5th, 7th, 11th, and 13th orders.
Compensation Results:
Harmonic current compensation efficiency up to 70% below 19th order
5th, 7th, 11th, and 13th harmonic currents reduced to meet national standard
Complies with GB/T 14549-1993 (Harmonics in Public Power Grid)
Dimensions
33~35kV Static Var Generator(SVG) – Indoor type | ||||
Voltage class(kV) | Rated capacity(Mvar) | Dimension W*D*H(mm) | Weight(kg) | Reactor type |
33~35 | 5.0~50.0 | 7400*7900*2600 | 9000~14000 | Air core reactor |
51.0~85.0 | 11500*7900*2600 | 15800~24000 | ||
86.0~100.0 | 16000*7400*2600 | 18000~28000 |
Applications
1. Renewable energy integration in solar and wind farms, intermittent generation causes voltage fluctuations, SVG offers:
2. Industrial power quality management heavy industrial loads often lead to voltage drops and low power factors, SVG offers:
3. Grid and Transmission Line Stability In long-distance power transmission, SVG offers:
About Us
With over 50 years of R&D experience since 1970, we are fully capable of meeting the grid standards of various countries.
For the past 20 years, we have been dedicated to the research, development, and manufacturing of SVG products. With steadily increasing customer satisfaction, we are confident in our ability to solve your power quality challenges.
Production Base: Jincheng Road, Economic Development Zone, Wenshang County, Jining City, Shandong Province, China
Email: overseas@fengguang.com
![]() |
FGI 33kV~35kV Indoor Static Var Generator Liquid Cooling Ultra Fast Response Intelligent Compensation Modular Images |